PRODUCT CATEGORIES

AEDER5 PARAMEDIC SERIES AED MANUAL MODE DEFIBRILLATOR / MONITOR - EXTERNAL ADULT & PEDIATRIC PADDLES - CU-ER5





  • Manual Mode – 20 steps escalating
  • AED Mode – 150J into a 50Ω load.
  • Reusable External Paddle (Adult, Pediatric) & Multifunction Defib. Pads
  • ECG Monitoring Mode (3 Lead, 5 Lead), SpO2 Monitoring
  • Heart Rate & SpO2 Alarm System
  • Automatic and operator initiated self tests


MODEL CU-ER5
Defibrillation:
ECG Lead Select
Waveform
Maxiumum Shock
Output Energy
 
 
Energy Accuracy
Charge Time
Shock Delivery
 
Patient impedance
AED Mode
Synchronous Cardioversion
Voice & Text
Prompts (AED)
 
I, II, III, aVR, aVL, aVF, V, Paddle/Pads, Ext ECG
Truncated Exponential Biphasic
20ms
Manual:  1~10J, 15j, 20J, 30J, 50J, 70J, 100, 120, 150J, 170J, 200J
AED Mode (Single energy output):  150J
Internal Paddle::  1~10J, 15J, 20J, 30J, 50J
1~10J : ±2J, 15~200J : ±15%
Less than 12 seconds to 200 Joules
Via multifunction defib electrode pads
External paddle (pediatric) or internal paddle (pediatric)
Shock Range : 25Ohm ~ 175Ohm
Shock advisory sensitivity and specificity meet AAMI DF-80 guidelines
Pads or External paddle, External ECG input
Voice & text prompts guide the user through the protocol
All the user interfaces are supported in local language for easy use and access
ECG Monitor:
Input
 
 
Lead Fault
 
Heart Rate Display
ECG size
Heart Rate Alarm
 
Lead I,II, III obtained through 3-lead ECG cable separate monitoring electrodes
With 5-lead cable obtain leads I, II, III, aVR, aVL, aVF, or V
“Lead Fault” message and dashed line displayed, if an electrode or lead wire becomes disconnected.
30 to 300bpm (±3bpm)
5, 10, 20mm/mV and Auto-gain
Less than Minimum setting rate / Over the Maximum setting rate
SpO2 Pulse Oximetry (Nellcor)
Saturation
Pulse Rate
 
 
70-100% (± 3 digits)
20-250bpm (±3bpm)
0.2%
Less than Miniumum setting rate / Over than maxiumum setting rate
Power source Internal Battery – Rechargeable / 12V 4.2Ah Nickel-Metal Hydride battery pack
Capacity – when new, minimum of 200 shock deliveries (200J)
Minimum of 4 hours for full charging
External Battery Pack – Disposable /12V 4200mAH Lithium battery pack
Capacity – when new, minimum of 200 shock deliveries (200J)
AC/DC Adapter – Input : 100 – 240V AC 50/60Hz 170VA
Output – DC 12V, 3.6A
Car Cigar Lighter
Jack DC 12V
Physical Dimensions  - Without external paddle : 254* 365*105(mm)
With External paddle :  455*365*105(mm)
Weight; 3.5kg (without Paddle)
Environmental Requirement
Temperature
 
Humidity
 
Operation: 0°C ~ 40°C
Storage: -20°~ 60°C
5% ~ 95%
Data Storage & Management Internal flash memory: 12 hours of event and ECG recording
SmartMedia Card (32M): 42 hours of event and ECG recording or 1 hour if voice recording is enabled.
Transmit multi patient data to PC  UART/ IrDA
Display LCD Dimensions - 4” diagonal (80mm*60mm)
High Resolution Mono Graphic LCD
Resolution - 320* 240 pixels
Wave Viewing Time - 3.2 seconds (ECG)
Sweep Speed - 25mm/sec
Back light -  EL Back Light
Automated Self-Test - Power On Self-Test / Run Time Self-Test / Manual Test
- Periodic Self-Tests (daily / weekly / monthly)
Standard Accessories -  Device
-  External Paddle (Adult, pediatric)
-  3-lead ECG Cable
-  Power cord
-  AC Adapter
-  Internal Battery (Ni-MH)
-  User’s Guide
Optional Accessories -  Date Card (SMC 32M)
-  Thermal Printer
-  Printer Paper (10 rolls)
-  Cigar Lighter Jack for Car
-  Multifunction Defib. Pads
-  Adapter for Defib. Pads
-  5-Lead ECG Cable
-  ECG Electrodes (50EA)
-  SPO2 Module Set (Probe, Extension Cable)
-  Disposable Battery Pack (lim02)
-  IrDA Adapter for Data Communication
-  Software for Data Management with Key File (UART cable included)







© Copyright Impact Medical Supplies. All Rights Reserved. Website designed and hosted by LIT Creations. You are visitor number: 1620017