| MODEL: | S6 |
| Display |
10.4” Diagonal Screen 640 x 480 Pixel Colour TFT |
|
Displayed Parameters: Time Alarms ECG Heart Rate NIBP Pulse Oximeter Respiration Rate Trends Temperatures Trace Freeze |
Battery-backed quartz crystal clock High & low limits selectable on patient parameters ECG Waveform Scale Derived from ECG or SPO2 Pressure (systolic, mean and diastolic) Pulse Rate, Pulse waveform and percent saturation Respiration rate derived from ECG HR, RR, NIBP, ST, TEMP, CO2 and SPO2 Two Channels Traces A & B |
|
ECG Display Gain Scales Sweep Speed Input Resistance Frequency Response CMRR Electrode Offset Potential Baseline Recovery Heart Rate Range Resolution Accuracy Alarm Lead off condition |
Standard Lead, I, II, III, aVL, aVR, aVF, Vx 2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s >5M Ohm (at 10Hz, not including patient cable) 0.05Hz – 100Hz (3dB) >80dB Maximum ±0.3V <5s after 5KV defibrillation 15bpm – 300bpm 1bpm <100bpm ±1% ≥100bpm ±2% Heart rate high and low limits alarm delay <12s Detected and displayed |
|
ST Segment range Accuracy |
-1.2mV to +1.2mV ±0.02mV |
|
SPO2 LED Specifications Alarm Display Display Update Resolution |
Range: 0% - 100% Accuracy: 80% - 100% ±2 digits, 70%-80% ±3digits, 0-69% unspecified Wavelength Radiant Power RED 660±2nm 1.8mW IR 905±10nm 2.0mW SPO2 high and low limits alarm delay <7s <5s 1% |
|
Pulse Rate: Measurement Range Resolution Accuracy Alarm delay |
20 to 250bpm 1bpm ±1bpm Pulse rate high and low limits alarm delay <7s |
|
NIBP Technique Patient Types Cuff Inflation Time Cuff inflation pressure Measurement Modes First Inflation Measurement |
Oscillometric method (with inflatable cuff) Determines systolic,diastolic and mean arterial pressures Adult, Pediatric and Neonatal 3-15s depending on cuff size Adult/Pediatric/Neonatal, subsequent inflation pressure determined by last measured systolic pressure Manual: Immediate upon operator command AUTO: Determinations automatically made with selectable intervals STAT: Determinations continues in 5 minutes Adult/Pediatric/Neonatal |
| Measurement Interval Time |
1 – 240min Step: 1 min (1min – 10min), 5min (10 min – 30min) 10 min (30min – 90min), 30min (90 – 240min) |
| Measurement Range |
Adult Systolic: 30mmHg – 225mmHg Diastolic:15mmHg – 220mm Hg Mean Arterial: 20mmHg~235mmHg |
| Measurement Range |
Infant Systolic: 30mmHg – 135mmHg Diastolic: 15mmHg – 110mmHg Mean Arterial: 20-125mmHg Pressure Resolution: 1mmHg |
| Accuracy |
Cuff Pressure Range: 0 to 275mmHg Pressure Span Accuracy: ±3mmHg Mean difference: ±5mmHg Standard deviation: 8mmHg |
| Determination Time | Typically 25s. Varies with patient’s pulse rate, pulse pressure and amount of artifact present |
| Overpressure Valve | Automatically releases cuff pressure if inflation pressure exceeds 280mmHg/150mmHg |
| Overtime Protection | Stop determinates if the measurement time exceeds 120s/90s |
| Alarm Delay | Pressure high and low limits alarm delay <7s |
|
RR Technique Range Resolution Accuracy Alarm delay |
Trans-thoracic impedance (RA-LL) 0-100 rpm 1 rpm ± 2 rpm (0-60rpm) Respiration rate high and low limits alarm delay <7s |
|
Temperature: Technique Channel Scales Probes Range Revolution Accuracy Alarm delay |
Resistance 2 (T1 and T2) F. or C. Resistive, recta and skin (reusable and disposable) YSI 400 Series types 0-50°C 0.1°C ±0.1°C Body temperature high and low limits alarm delay <7s |
| CO2 (Optional) | |
| IBP (Optional) | |
| Power Requirements | 100-240VAC, 50/60Hz 1.6A max |
| Internal Battery | 12V 7AH, typed-sealed lead-acid |
| Operating Time | 2 hours typical at 25°C, no printing, one NIBP measurement |
| (fully charged battery) | Per 15 min |